11 ton light oil fired boiler for chemical industry
Image gas 11 ton fired boiler for chemical industry (4) of the fan impeller, air guns fire tube, damper controller, damper baffle, a cam adjusting mechanism diffuser plate. 2, the ignition system functions in that the ignition system ignites a mixture of air and fuel, its main components are: the ignition transformer, the ignition electrode, a high voltage electrical cable fire. A more secure electronic ignition system called ignition pulse, is widely used Zhuoyi energy saving gas boiler manufacturers. Which facilitate saving, can simply press a finger, and safe, does not occur due to unexpected accidents occur flame, once the stall state occurs, the control system can close the solenoid valve, off the gas passage. 3, system monitoring function monitoring system is to ensure that the burner safe and stable operation, the main components are flame detectors, pressure monitor, temperature monitor (see below) and the like. 4, functions of the fuel system of the fuel system is to ensure that the desired fuel burner. The fuel oil burner system are: tubing and fittings, pumps, solenoid valves, nozzles, heavy oil preheater. The gas burner mainly a filter, pressure regulator, solenoid valve, and then firing solenoid valve, the fuel valve. 5, electronic control system electronic control system command center and the focal the above system, the primary control element is a control box, for different burners with different programmable devices, the common programmer has: lfl series, LAL series, loa series, LGB series, the main difference is the time of each different program steps. The controller 1, ultra Encyclopedia Chinese LCD display, built-in luminous incandescent lamp, regardless of the day night, the screen clearly visible. 2, the image level animation display state, condition, valve status, alarm status, operation of the boiler at a glance. 3, cpu intelligent central processor, all the programs focused on a digital chip, scalability, high degree of automation, simple, and powerful. 4, includes a time setting, temperature setting, setting valve, a continuous setting, timer setting, and other control functions pressure setting, arbitrarily set the working state.
As to paper carton box production factory, it has similar requirements to other paper factories. It needs steam, tons of steam in carton box production lines. WNS series 11 ton fired boiler for chemical industry can burn gas fuel and oil fuel. To reach highest thermal heat transferring efficiency, boiler users should use the designed fuel. ZG Boiler also supplies boiler transforming service. We can transform coal fired boiler into biomass boiler, oil fired boiler into gas fired boiler.
February 13, 2019, a food processing plant in Heilongjiang province, after the Spring Festival to resume production process, 11 ton fired boiler for chemical industry explosion accident occurred, killing two people were killed, to the masses lives and property of people come at a cost, resulting in adverse social impact .
To reduce boiler accident, maintain social stability and security personnel, Suihua City Market Authority to act quickly, on February 15 Kusakabe issued an emergency notice to deploy to carry out safety hazards investigation boilers within the city, the focus of the investigation after the Spring Festival recovery boiler operation baths and other crowded places in boilers, boiler timely elimination of security risks in the management and operation aspects of existence.
As of now, law enforcement officers deployed 116 times, check unit 52, checks the boiler 64 for five in the boiler there are security risks of Special Equipment Safety Supervision issued a letter of instruction, ordered to stop using, be put into use after the rectification qualified.
The reason the gas 11 ton fired boiler for chemical industry burner increased noise analysis when making use of the gas boiler and found this small fire normal, but this time turn the fire, extinguished or flashing instability. First speaking, that is because of this fire damper of the air volume setting is too large; i.e. after an oil fire because the micro-switch valve (damper outermost that group) inappropriate setting (set lower than the fire damper of the air flow larger) burner gas noise increases, mostly because the oil shut-off valve which is closed or lack of oil into the oil filter clogging; or, this is because of low temperature into the oil, the viscosity is too high or the pump into the oil temperature is too high; oil pump failure; fan motor bearing damage; there is because the fan impeller dirty equipment resulting in large noise. The above-described failure when using gas boiler, but also because the viscosity is too high oleaginous easy to be atomized (heavy oil); cyclones and because improper disc and the nozzle pitch; Note that because the fire is worn or dirty nipple; also because this preparatory tank the heating temperature is too high, causing the oil pump oil feed steam does not conform; or because the fuel inside the boiler resulting aqueous oil. When the above-described fault gas boiler used to perform this process, the test should be done gradually decreases; after heating temperature should be; adjusting the distance (between 0 ~ 10mm); clean or replace; is set to about 50 deg.] C to about; or drain oil change.