efficiency boiler super high pressure boiler
Features Features of the hot water efficiency boiler super high pressure boiler hot water boiler characteristics of low-nitrogen boiler water: results are as follows: 1. Henan fast boiler low nitrogen gas hot water boiler compact three-loop structure, the structure of the wet. 2, threaded pipe heating a low nitrogen gas hot water boiler smoke tube, a spoiler, a heat transfer enhancement effect. three. Before and after heating a low nitrogen gas hot water boiler, removable smoke box doors, easy maintenance of the boiler. four. Low nitrogen gas hot water boiler heating body according to need galvanizing, hot water to provide a clean and hygienic. 5. By setting the burner and the circulation pump start and stop temperature, the control system automatically operates in accordance with set conditions. Meanwhile, operation of the system may be displayed, to achieve the return water temperature measurement. Alarm message is displayed in case of failure. 6. In the manual state, the circulating pump and the burner can be run directly, appropriate instructions can be given fault. Reject manual operation, the system is safe. 7. Flue gas outlet condensing heat exchanger can be installed. Reduce exhaust gas temperature, flue gas absorbing sensible heat and the latent heat, to improve the thermal efficiency of the boiler. A liquid crystal controller or a touch screen control, a high degree of automation, simple operation. With combustion, water temperature control, leak detection alarm, over-pressure, over-temperature, water protection, interlock protection, the timing of antifreeze and other functions. And a graphic display control section Chinese system status, fault diagnosis according to user requirements on exhaust emissions, the respective boilers and burners meet the requirements of low nitrogen emissions! Costs accounted for separately.
After the meeting, accompanied by dealers to observe the company's leadership in the clean efficiency boiler super high pressure boiler laboratory, set comprehensive performance test platform (energy efficiency testing), the burner test platform, systematic energy saving technology and demonstrate real boiler room, Transfer Intensification testing center, centralized control system and other functions, the maximum test capacity of 40t / h, the maximum installed capacity of 40t / h, is to demonstrate, on a test basis technical research products, set in a comprehensive testing center.
Control measures Henan four gas efficiency boiler super high pressure boiler leaking 1, perfect wear, new technologies, new ways to increase the use of anti-corrosion measures Henan gas boiler service life. The water wall tube burner region, in particular weld position, serious high temperature corrosion, high temperature corrosion to prevent the use of new corrosion-resistant materials. 2, to strengthen the operation and management of Henan to promote over-temperature monitoring gas boiler heating surface running, to strengthen the technical analysis of the phenomenon of over-temperature. Henan gas boiler operating personnel required to correctly handle the relationship between safety and efficiency, access to information ahead of fuel, equipment, operation mode, etc., to strengthen the burning adjustment. Strictly control the heating and cooling units appear excessive speed during start and stop, hydrostatic testing and operation, over-temperature overpressure operation and combustion instability phenomenon, while strengthening quality supervision. 3, Henan reinforcing and wear proof test gas boiler inspection check baffles cover wear, wear shoe is intact and columns where the discharge tube; tube wear after checking flue gas damper temperature control device. For the water wall, in the vicinity of high temperature corrosion Wall thinning inspection combustor case; waterwall fin weld inspection, fouling and coarse diameter expansion, the temperature of the medium between the two sides of the fin tube and leave some margin expansion. In the case of the fillet weld superheater and reheater key checks the header of the nipple. 4. actively train service operator Henan excellent gas boiler maintenance operations personnel can effectively reduce the probability of occurrence of leakage of boiler plants. Therefore, the plant should actively provide scientific and reasonable training for boiler maintenance personnel to improve their technical level of maintenance and repair of Henan gas boiler, boiler maintenance and repair technology to enhance operational competence of personnel. 5. sound design appropriate to increase the margin of safety is a fundamental measure designed to "four" Crack Prevention. The arrangement of the heating surface design, the furnace hot strength steel, cross-mixing and expansion system considered reasonable, it will greatly reduce the occurrence of burst leakage.
Small efficiency boiler super high pressure boiler water volume, faster heat transfer, either warming or boost quickly. After 5 minutes the ignition to start the output of hot water and steam required, and water separator with a high performance, to ensure the quality of steam and hot water.