electric hot water boiler system in egypt
Electric electric hot water boiler system in egypt supplying domestic matters need to pay attention what? 1, electric boiler carefully check each system before opening oven parts electric boiler, focused on checking the three security controls pressure gauge, safety valve, gas pipe fittings, water level is normal, everything is correct, put on compliance clothing to continue to work. Electric steam boiler 2, please do one-handed operation when the water in the electric boiler, water regulatory action is single-handedly opened the door in one hand and a water injector steam valve, when the water column to a predetermined level, the first valving (valving time face not being on the water, to prevent splash injuries face) and then turn off the water gate, electric boilers provide domestic water to be alert order can not be reversed. When electric boiler work, surrounding someone must guard the moment the water level and pressure gauges, there can be no neglect of duty, to adjust work schedules when working at night, night shift work, be sure to have a good rest during the day, not at night when this work I would doze off, because if there is any carelessness, accidents will happen. Points to note what? 4, electric boilers night to the boiler daily sewage treatment, water table should clean up once every night. For motor and other mechanical equipment have always been its inspection, if any abnormal findings, the investigation must be immediate. Weekly safety valve should be checked whether it is safe.
Principles of steam electric hot water boiler system in egypts and solutions hydraulic external gear of Henan fast boiler's small series with you about the principles of steam boilers and solutions Steam Boiler hydraulic external gear in accordance with the fuel (electricity, oil, gas) can be divided into electric steam boilers, oil three kinds of steam boilers, gas and steam boiler; constructed according to the steam boiler can be divided into vertical, horizontal steam boiler, steam boiler compact than a single, double return of the vertical structure, large steam boiler return of more than three horizontal structure . If the classification according to top standards, in the form of steam boilers on the lot, would like to give an ordinary packaged boiler say four tons vapor. Water in the steam drum is heated to become vapor, fire emits heat in the furnace, it is the principle of the steam boiler. Steam boiler combustion section and drive means by a chain grate, a combustion chamber together with the pan rack frame formed on a grate composition. Four weeks envelope refractories. From coal fired into the hopper, the shutter coal front portion while sealing air control seam thickness. Blowing into the combustion chamber is a lower place, such steam boilers greater resistance, require forced air. Steam boiler cinder burn out, the rear portion of the grate by the "beak iron" discharged from the slag out of the furnace feeding machine. Steam boiler flue gas from the back of the boiler, the steam drum of a boiler return line before the smoke tube, returned by two return rear smoke tube, and then into the dust separating ashes, and then discharged through the chimney draft fan. These are the works of steam boilers, steam boilers run course, ultimately, other devices, such as induced draft fan not only bear the task of exhaust fumes, or negative pressure necessary for operation of the steam boiler. As well as pressure vessels, thermometer, safety valves, pressure gauges, pumps, steam pumps, and so on. They are essential for steam boiler work. Pump leaks. Gear pumps for leaks during operation, leading to its actual output is smaller than the theoretical flow of traffic. The main channel is leaking gear pump: through the gap between both surfaces and both side surfaces of the gear cover side leakage, accounting for 75% to 85% of the total leakage of the pump; radial gear tip circle between the inner hole and the pump CLEARANCE ; gap by engagement of the gear leak. The gear pump due to the presence of a leak, so that the output pressure do not increase, the influence of the use of a gear pump. In order to solve the low gear pump output pressure problems, may be employed on both sides of the elastic gear plus floating collar or baffle manner, to reduce the leakage of the gear pump, the gear pump to increase the output pressure. Radial force imbalance. In the gear pump during operation, the pressure acting on the outer gears are not equal, resulting in the gear and bearing at the axle radial imbalance force. This unbalanced force will accelerate the radial bearing wear and reduce the service life of the bearings, the gear shaft deformation can also cause friction with the inner hole of the addendum pump, pump damage, so that the pump does not work. The solution generally adopted is: ④ opening pressure balancing grooves to the pump, the high pressure oil introduced into the low pressure zone, but will increase the pump leak, the influence of the volumetric efficiency of the pump; ② size reduction oil pressure chamber, acting on the teeth the pressure area is reduced, thereby reducing the radial force imbalance.
1 electric steam electric hot water boiler system in egypt maintenance, maintenance when the boiler must be cut off and must relief. 2, the burner every two months to be removed from the boiler, carefully remove foreign bodies such as dust and soot. Photocell light-receiving surface wipe once a month, fuel filter should always be kept clean and filtering capabilities; carefully clean the filter in the pump, do not break the seal. Oil-burner not idle, so as not to damage the pump. 3, the water level gauge should always be kept clean, rinse the purge valve is opened, the water level in order to ensure a clear day. 4, pulling the safety valve once a day, to prevent rusting failure. 5, the boiler stops longer running time, cut off the power, and do maintenance work: (1), dry maintenance, shutdown after the release came out water, dirt clean the furnace, slow fire the pot with a burner after drying (burn time not too long, to avoid damage to the boiler), then drain all of the gas boiler, all pipe valve closed, checked every three months. (2), wet maintenance for a period not exceeding one month shutdown of the boiler, furnace shutdown after water release, discharge and clean fill with water, cut off the power, close the valve.
Further promote air pollution control work, the Office of the ecological environment of Shanxi publicly stated: Shanxi Province will strictly control the total coal consumption; reduce the proportion of coal in primary energy consumption; Where ban on coal sales area of coal and coal products, both will be subject to heavy penalties.
Shanxi Province has also developed regulations, Municipal People's Government in accordance with the requirements to improve the quality of atmospheric environment, urban built-up area designated as the ban on coal zone, and gradually extended; counties (cities, districts) People's Government may delineate the scope of ban on coal zone according to the actual situation but life should be a primary consideration the needs of local residents. In addition to coal coal ban areas, central heating and raw material coal companies, prohibit the storage, distribution and burning of coal and its products.
At the same time, governments at all levels in Shanxi province will also strengthen civil bulk coal management, prohibit the sale, does not meet the civil standard of quality coal for coal; prohibition of lignite, coal washing, slime and other low-quality, low-grade coal as a civilian coal use. Various localities will accelerate the cogeneration and district heating coal heating in the region. In the central heating pipe network coverage area, prohibit new construction, renovation, expansion of distributed coal-fired heating boilers; central heating pipe network coverage prior to the completion of use of scattered coal-fired heating boilers have been built and can not meet emissions standards coal-fired heating boilers, demolition will be completed within the deadline.
For violation of the provisions, sales do not meet the quality standards of civilian coal for coal, or the ban on coal sales coal region and its products, the people's government above the county level by the market supervision and management department confiscated of raw materials, products and illegal income, impose a fine of three times the value of the amount more than doubled.