filling bottle gas fire tube boiler dealer
Fangkuai Company has a fully-automatic PLC intelligent control system designed and developed by itself with complete intellectual property rights. It adopts a combination of mechatronic control equipment and a programmable logic controller (PLC). Take the advanced programmable logic controller (PLC) as the "central processing unit" of the control system. The control system is operated through the touch screen, which greatly improves the degree of automatic control and operation reliability of the filling bottle fire tube boiler dealer, and the operation is simpler and more intuitive.
For filling bottle fire tube boiler dealer burners, you know how much: the burner is one of the important equipment a decision whether the normal operation of the boiler, burner now divided into oil burners, gas burners and dual fuel burners (also known as two oil and gas burner). Users in the purchase of the boiler, burner should be judged, then, how much do you know about the knowledge burner it? Here to talk to you one by a small series. Burners belonging to a higher degree of automation of the electromechanical equipment, which need to achieve a functional point of view, can be divided into five systems: air supply system, ignition system, monitoring system, a fuel system and electric control system.
6 tons adjusting a combustion gas steam filling bottle fire tube boiler dealer, normal combustion boiler three basic aspects of indicators include a uniform supply of the fuel, reasonable ventilation, adjustment the combustion. 1, to maintain the high temperature of the combustion chamber temperature of the upper layer is preferably in the 1100 ~ 1300 ℃, flame orange in color. Flame reddish color indicates that the amount is not enough to the wind, the color white indicates that excessive wind. It should be appropriately adjusted. 2, fuel ash to reduce ash content in the combustibles to be below 10%. 3, reducing the temperature of the boiler flue gas exhaust gas temperature should be controlled below 200 ℃. 4, holding furnace negative excess air boiler is 1.2 to 1.4, by adjusting the balance of the blowers to maintain the furnace pressure is -20 ~ -30Pa. 5, the thermal efficiency of the boiler to improve the thermal efficiency of the boiler should be kept above 60%. II. Combustion Adjustment 1, the amount of fuel to air required for combustion and the amount of a reasonable distribution. Ventilation should first increase the amount of fuel increases, it should first reduce the amount of fuel supply reduced ventilation. 2, the thickness of the seam and seam thickness configuration grate speed is 80 ~ 120mm grate speed at high, middle and low profile configuration of several commonly used methods:. 9a rapid combustion of thin seam b c thick seam in low combustion. 3 thick seam combustion speed, the segment with the wind blowing principle: burn promoting intermediate ends. That is, after the coal into the coal starts to warm up the shutter, fire line front arch, the primary combustion zone, the middle grate to burn the rear grate zone. Normal combustion conditions are: fuel from the coal at the beginning of the fire shutter 300mm, uniform flames, the fire bed formation, at the end of combustion from the end of the grate 300 ~ 500mm. 4. maintain proper furnace temperature to avoid coking. The fire bed to maintain the homogeneous combustion, to avoid burning fire bed obliquely. 6. The residence time of the fuel on the grate in less than 30 minutes.
Gas oil furnace instructions and operating permits gas pressure determinants: conducting oil furnace oil furnace gas, below, we will continue to learn and understand the products, because its site is not just products, but , one of the main keyword or website, so will the above work. And this for all of us, it is a great learning opportunity, so I hope we can be taken seriously and, so, to make their own benefit. 1. If the worker holds operating permit coal-fired thermal oil heaters, then, can be operated using the gas oil furnace? This, then, at block filling bottle fire tube boiler dealer view, is not possible because: coal-fired boilers and gas boilers, although they all belong to the boiler, but in the professional operation certificate, is not the same, because these are two different properties boiler. Coal and gas and oil furnace oil furnace, they belong to coal-fired boilers and gas boilers, therefore, will have above this conclusion.