gas oil fired burning steam boiler factory
In recent years, the increasing popularity of Yichun City, Jiangxi Province comprehensive energy saving coal-fired boiler upgrade project, plans to eliminate 75% of the downtown 10 steam tons / hour and below the coal-fired boilers, a ban on new 20 tons of steam / hour and less fuel coal boilers; the rest of principle, then the new 10 steam tons / hour of coal-fired boilers.
Following this, Jiangxi Province Department of Finance issued a special subsidy fund boilers, Yichun downtown 2015--2016 phase-out 10 steam tons / hour coal-fired boilers companies grant. The subsidy standard is: 2 out of steam tons / hour and coal-fired boilers, subsidies to 10,000 yuan / Taiwan; out of steam 2-10 t / h coal-fired boiler, subsidies for 20,000 yuan / Taiwan.
About hot water boilers including hot water boiler electric water boilers, hot water boiler fuel, gas hot water boilers and coal-fired hot water boilers, hot water boilers that produce hot water boilers, is the use of the thermal energy released from fuel combustion or other thermal energy (e.g., electrical energy, solar energy, etc.) the water was heated to a nominal temperature of a thermal device. "Special Equipment Safety Supervision Regulations" as defined in the boiler is the use of various fuels, electricity or other energy sources, the costumes, the liquid is heated to a certain parameter, and external heat output devices. Which is defined in a range equal to or greater than the volume of the pressure of the oil fired burning steam boiler factory 30L; outlet pressure is greater than or equal to 0.1MPa (gauge pressure), greater than or equal to the rated power and the pressure of the hot water boiler 0.1Mw; organic heat boiler. From "Special Equipment Safety Supervision Regulations" Uses People's Republic of China: There are heating and hot water boiler bath for two purposes. Hot water boiler by circulating hot water circulation pump hot water holding tank, the tank hot water heating cycle can be achieved bath object; hot water boiler by circulating hot water circulation pump heating conduit, through the heat sink (radiator) people can achieve heating requirements; hot water boiler and hot water circulating pump with heat exchanger can achieve the dual function of bathing and heating using inspection items include: checking in the internal boiler inspection and ready to use, furnace and flue boiler inspection accessories check check, auxiliary equipment automatic control system, check the combustion equipment, check the auxiliary heating surface of the hot water boiler must be done before running some tests, these tests are quite a lot of us, it is possible because of our neglect causing very serious consequences. Therefore, we must forestall, be sure to carefully check the following before the hot water boiler operation. 1, including the use of internal inspection and boiler ready. 2, inspection, and furnace fouling and debris inside the flue in the furnace and flue should be cleaned. Flue duct and damper, the shutter must be complete and compact, flexible switch, opening and closing accurately indicated. 3, check the boiler accessories, check the safety accessory is intact; cock is rotating flexible, easy to use; all kinds of instruments and controls should be complete, good, clean. After passing the examination, should the gauge cocks in working condition. 4, check the automatic control system. 5. Check the accessory device. 6, inspection of the combustion apparatus, the combustion apparatus is intact inspection; mechanical transmission system, coal handling system, the ballast system test switch normally; spring-loaded safety level of a gearbox should be appropriate, well lubricated; coal shutter indicate the correct scale. iron eagle neat, well, turn the ballast plates full, flexible movement. 7, the auxiliary heating surface of the inspection, check the auxiliary device (fan, blower, pump, etc.) are firmly connected coupling; proper belt tension triangle; oil should be good enough; cooling water flow. After passing the examination, installed security guard, respectively, commissioning, and note the current when idling.
Water Tube Oil Gas Fired Boiler is D Type in which water circulates in tubes heated externally by the fire. Fuel is burned inside the furnace, creating hot gas which heats water in the steam-generating tubes. D Type Water Tube Oil Gas Fired Boiler in ZBG is designed with a large steam drum at the top, vertically connected to a smaller water drum (or “mud drum”) at the bottom, via multiple steam-generating tubes which carry feed water (providing the main heat transfer surfaces for the production of steam). These are surrounded by walls made up of larger water-filled tubes, named membrane water wall, and all of them form the boiler.
Fuel oils burned in boilers include the heavier oil, diesel oil and others. As a liquid, fuel oils are relatively easy to handle and burn. In most oil boilers, the oil is atomized with air, steam, or pressure to enhance combustion. The characteristics of atomized oil approximate those of natural gas. The heating value of fuel oil is derived primarily from its two major constituents, hydrogen and carbon. Most fuel oils have a hydrogen content that ranges between 10 and 14%, and a carbon content that ranges between 86 and 90%.