gas vacuum fire tube boiler dealer in indonesia
Our hospital requirements for environmental protection, health and safety in these areas is very high, for a wide variety of market boiler is also very headache and confusion, there fast boiler solve the above problem, the boiler set clean environment to provide for our hospitals and efficient operation in one, coincides with the philosophy of our hospital. --customer feedback
Hot water boiler tank size is defined determinants and small boilers: hot water boiler, which is a boiler, and, for common and common species, therefore, be familiar with and understand it, is necessary, because in practical work may encounter and use this kind of boiler, therefore, we will have the need to know. And here are some specific issues to expand through this work. In this way, we are also capable of deriving some expertise, rather than nothing. 1. The hot water boiler tank, its size is determined by what? Hot water boiler tank, which should refer to the boiler tank with the water pipe network, rather than directly to the boiler water tank is mainly used to store oxygen or demineralized water. The tank capacity is determined by the size of the fill water of the hot water boiler. In the design of the boiler, is generally calculated according to the cycle of water 3% -5% of the fill water boiler system. 2. The need to gauge pressure hot water boiler in? In addition, vacuum gas boiler, hot water boiler which is it? Pressure hot water boiler, which is a hot water boiler, which boiler the host, there is communication with the atmosphere of the conduit, so that the boiler remains at normal pressure. So, this kind of boiler, does not require installation of a pressure gauge. And vacuum gas boiler which are generally hot water boiler.
(2) fuel (gas ) vacuum phase change boilers, such as vacuum phase change boilers, adopt imported burners, which have high combustion efficiency, low noise and exhaust gas emissions. Internal use of stainless steel exchanger, on the one hand to ensure high heat transfer efficiency, on the other hand, to ensure clean water quality. At the same time, the smoke tube is equipped with spiral spoiler to improve the heat transfer efficiency and reduce the operation cost. In addition, it adopts a square structure, boiler and heat exchanger designed as one, making its structure compact and small shape beauty. Through the above classification of vacuum phase change boilers, and the description of the different types of The characteristics, so that everyone to its relevant knowledge to achieve a number of.
The comparison of boiler failure rate: 1, vacuum degree of vacuum boiler in vacuum boiler * important index of stable operation of furnace, and four main factors that often affect vacuum degree: 1) whether there is leakage point in boiler body and valve, instrument, and so on. At present, including imported valves and meters can not ensure that there is no leakage within 3 years. 2) it is inevitable that failure of control part, boiler controller and negative pressure, pressure controller will also happen in operation, for example, the failure rate of domestic controller is even higher. 3) vacuum pump, three-way solenoid valve is working normally or not. As a result of the vacuum pump, the three-way solenoid valve is not operating very often and is originally installed Mouth also easy to appear the card dead and in the operation occurs the fault. 4) the load can not change abruptly, the boiler load change is very normal for the boiler, generally, the boiler can meet the load regulation of 30% ~ 100%. The above faults will cause the change of the vacuum degree of the boiler. At this time, the gas tightness of the boiler, whether the control part is normal or not, the vacuum pump, the three-way solenoid valve are normal or not, and the change of load should be checked. If all normal should be checked negative pressure and pressure controller settings, all normal vacuum recovery boiler can still be normal, otherwise the boiler should be shut down and overhauled all-round inspection. The failure maintenance rate of vacuum boiler in actual operation is higher than that of existing boiler. Pressure steam boiler, control requirements are higher than steam boiler. 2. The normal pressure boiler only has the basic time, temperature, water level control, hot water boiler controller selected the original inlet, the failure rate is relatively low. There is no need to maintain vacuum control equipment, without complex control equipment, personnel operation requirements are simpler than vacuum boilers, the probability of downtime maintenance is less, the actual operation of hot water boiler is much more stable. The comparison of boiler safety: 1. If the vacuum degree of the vacuum boiler is not guaranteed due to the above four factors, it may cause the boiler pressure to rise rapidly, and the boiler body is a closed structure, and the operator may cause the boiler pressure to rise rapidly. If paralyzed, it is possible to become the danger of pressured steam boiler, the vacuum operation of vacuum boiler is more safe based on the premise that the vacuum degree of boiler can not appear problem. 2. The atmospheric hot water boiler of atmospheric pressure boiler is as simple as boiling water, and no fault will cause boiler pressure. The boiler www.boilermanufactory.com is more safe and reliable, and it is really free of any danger.