high efficiency szs gas fired boiler steam heating
Teach you how to properly operate a steam high efficiency szs fired boiler steam heating: steam boiler before use to conduct the inspection of the damaged insulation, burner check to see whether the normal operation, also check to ensure that the open position of the valve is correct, check the device controlled device instrumentation and safety equipment accessories, equipment must meet the requirements. Steam boiler furnace entry point confirmation are: Open the valve before and after the oil circulation pump, oil heating flow valve opens, the liquid level in the sump reasonable mediate high position, confirmed that the gas pressure before ignition of the gas burner to the range, the power supply is normal .
Steam high efficiency szs fired boiler steam heating steam boiler price Price: works steam boiler is heated in the drum and water is converted into steam, fire gives off heat in the furnace. Qiang boiler plumbing materials sales center is located in the southern suburbs of Datong City, is a design, sales, installation and service of integrated modern enterprise management. The main environmental operating boiler, a steam boiler fired boiler, a heating furnace, steel radiators, cast iron radiators, canned motor pump, the pump piping, air-conditioning water, galvanized pipe, PP board tanks. Details can be found! Works (in Pulverized example) in the furnace pulverized coal combustion heat is first absorbed water wall heat transfer by radiation, boiling and evaporation of the water wall to enter a large amount of steam for steam separator drum (excluding the DC furnace), into the separated saturated steam superheater heated by flue gas at the top, and the horizontal flue gas flue continue to be absorbed radiation and convection, superheated steam reaches a predetermined operating temperature. Generating boilers usually equipped with a reheater is heated by high pressure steam cylinder. Reheater steam power generation is continued into the low pressure cylinder. 1, the working principle (as an example in pulverized coal fired boilers) in the furnace pulverized coal combustion heat is first absorbed water wall heat transfer by radiation, boiling and evaporation of the water wall to enter a large amount of steam for steam separator drum (except for the DC furnace ), the separated saturated steam enters the superheater heated by flue gas at the top, and the horizontal flue gas flue continue to be absorbed radiation and convection, superheated steam reaches a predetermined operating temperature. Generating boilers usually equipped with a reheater is heated by high pressure steam cylinder. Reheater steam power generation is continued into the low pressure cylinder. 2. Pulverized coal boiler operation, the position of the center of the flame will affect evaporation. Generally, low center of the flame will lead to greater evaporation, and the high center of the flame will lead to slow evaporation. Also affects the position of the center of the flame superheated steam or reheat steam temperature. Typically, superheated steam, in particular the reheat steam temperature in the lower center of the flame, and vice versa. 3. Pulverized Coal Burner front and rear walls is arranged a thrust manner, tangential firing mode, bis tangential firing methods, each method has its own characteristics. Since the above-described arrangement can not be applied in the same furnace at the same time, the influence of steam can not be directly determined.
"Thalia T7" The launch will greatly resolve hotels, supermarkets, enterprises and other energy problems and low nitrogen integration, and promote clean heating reform, promote the development of clean heating industry, the posture of the strong start another wave.
Successful ignition of fuel steam high efficiency szs fired boiler steam heating can not run, because of those common oil gas powered steam boiler applications, all of you should ignite the fuel steam boiler in the application process, no way ignition is also the most common problems. Fuel steam boiler in the application process, most likely resulting in no way ignition, resulting in fuel steam boiler can not run normally, small series to introduce you to a steam boiler does not ignite the fuel to run those common reason. Fuel steam boiler can not run common ignition of those reasons: First, the ignition problems: pulse ignition and control systems such as the one of which has caused the problem, the fuel steam boiler can not start. Second, the battery thing: to be very important to see if the battery is a battery in the end is not too aging. The charge is not standard, the same can not let steam boiler fuel ignition. Third, the water pressure thing: at the inlet steam boiler fuel filters block the formation of water can not flow normally through the clean up clean ok. Fourth, the pulse valve problems: If the boiler ignited fuel vapors to ignite division saw sound, no pulse valve "despair" squeak, probably for the pulse valve is damaged or degraded, pulse valve degeneration, will not manipulate, the beginning of the ignition operation when closing a flow will hit a fire, but the fire immediately and confinement; pulse valve before confirm whether there is a problem to confirm whether normal ignition actuating member, if the fault can not pull the valve actuating pulse. V. ignite feelings needles or needle thing: fuel steam boiler ignited hand shift. You can change or correct the ignition pin arrangement; if feelings of degradation promise things, as long as the feeling wiped clean arranged on it. Six, usually no way to exhaust smoke tube. Smoke tube steam boiler with a fuel block, clean breathing tube blockers smoke tube is too long, the configuration is not correct. Referring may be configured to inform two coaxial cigarette heater tube. VII vapor setter joint problems: fuel steam boilers, water vapor degradation intimal flap valve or joint damage, not the weak control push button switch; weak bad control switch button.