horizontal gas fired condensing boiler
In order to promote technological progress and sustainable development, improve environmental quality and protect public health, recently, the Liaoning Provincial People's Government of air pollutants for coal-fired power plants developed specific criteria (hereinafter referred to as the "standard"). This is the first time a set of policies Liaoning Province for air pollutant coal power plant.
"Standard" provides for pollutant discharge limits, surveillance and monitoring requirements within the jurisdiction of coal-fired power plant in Liaoning Province atmospheric and fugitive emissions control requirements. Since the implementation of the standards, air pollutant emissions coal-fired power plants all within the jurisdiction of Liaoning Province will be executed in accordance with the provisions of this standard.
2, since January 1, 2019, the emission limits of existing single output and more than 300MW generating units supporting the provision of a coal-fired power generation boilers execution table.
3, since 1 December 2020, the emission limits of existing single output 300MW generating units supporting the coal-fired power generation boilers and other power boilers as specified in Table 1 execution.
Sampling the exhaust gas (1) power plant, to be carried out in a predetermined position in accordance with the type of monitor emissions monitoring contaminants. In the discharge of pollutants should be set up to monitor the position of long-term monitoring holes, sampling platform and related facilities. When the sampling platform height from the ground greater than 40m, should be set by a lift platforms, lifts or other convenient and safe facilities. No elevator or elevator building coal-fired power plants, when the sampling platform height from the ground greater than 20m, should be set up safe, convenient electric monitoring equipment hoisting facilities.
Composition structure (3) continuous monitoring system atmospheric pollutants, technical requirements, test items, test methods and installation, commissioning, acceptance, operation management, data processing, etc. according to the provisions of HJ75 and HJ76.
(5) continuous monitoring system meter of air pollutants detection sensitivity, detection limit, and should meet the range of low concentrations of pollutant emission monitoring technical requirements, the concentration of nitrogen oxides include nitric oxide (NO) and nitrogen dioxide (of NO2), Determination of nitric oxide only has the ability to configure the analytical device of nitrogen oxides NO2 / NO converter.
(7) for coal-fired power boiler emissions of air pollutants sampling monitoring, sampling frequency, the sampling time and the operating load requirements,, HJ / T397 and related predetermined low exhaust gas concentration monitoring is performed according to specifications GB / T16157.
(9) shall be in accordance with the provisions of the enterprise "Environmental Monitoring and Management Measures" and the HJ819, HJ820 requirements of pollutant emissions and its impact on environmental quality around to conduct their own surveillance, monitoring and save the original records, public information.
Determination of air pollutants fired power plant analysis are shown in Table 2. After the release of the present embodiment national standard method of monitoring criteria pollutants, such as applicability to meet the requirements, the same applies to the determination of the corresponding standard contaminants present.
2, responsible for overseeing the management of this standard by the executive authorities and the standardization of administrative departments above the county level environmental protection. The results of the environmental protection departments at all levels and other relevant units in the enterprise supervision and checks can be instantly sampled or monitored the scene as determining whether acts of sewage meet emissions standards based on the relevant environmental protection and the implementation of management measures.
2. Energy-saving horizontal diesel horizontal fired condensing boiler
The oil and gas boiler produced by ZG boiler uses a large volume design of the combustion chamber to make combustion more fully and save fuel.
The ZBG oil and gas horizontal fired condensing boiler can be used for different industrials: textile plant, paper industry, chemical plant, food & beverage, garment manufacturing, printing and dyeing mill, cement plant, fertilizer plant, rice mills, rubber factory, schools, hotel, bath center, swimming pool, hospital, etc. And our boilers are all tailor-made. They are designed all depending on your business, including on the fuel, capacity, pressure and so on you need. We provide solutions and price information to our customers based on their needs. We provide solutions and price information to our customers based on their needs.
20 tph WNS gas-fired steam horizontal fired condensing boiler for milk products plantThe production and processing of dairy products require a large amount of steam to distill, disinfect, dry, and shape the food. The customer's boiler house is arranged in a single layer. After our technical staff visits the site and communicates with customers, ZOZEN decided to use two units of 10 tph oil and gas dual-use steam boilers in this project. This type of boiler adopts a mechanical and electrical integration structure, generous appearance, less investment in infrastructure; our boiler is strictly in accordance with the requirements of the customer to complete the standard, and we provide full equipment debugging, technical guidance, regular return visits, collection Feedback, which makes customer relieved and satisfied.