how much is 11ton gas steam boiler
15 tph SZL coal-fired water tube boiler project for gelatin industryNTP Gelatine Pvt. Ltd., established in 1957, is a leading gelatin manufacturer in Pakistan. In the manufacturing process of gelatin, plenty of high-quality steam is needed in extraction, concentration and drying, therefore, one set of how much is 11ton steam boiler with sufficient output and high quality is critical to the production line. The previous coal-fired steam boiler of NTP Gelatine Pvt. Ltd. had a considerable impact on the production due to inadequate combustion and insufficient combustion, so the company decided to reorder one set of efficient coal-fired steam boiler. ZOZEN coal-fired boilers have outstanding advantages in product design, quality and performance, which were highly appreciated by NTP Gelatine Pvt. Ltd. ZOZEN sales manager conducted a field investigation to inspect the actual working conditions and provided a set of 15 tph SZL series coal-fired water tube boiler. This series of boilers has wide fuel adaptability, and is suitable for many types of coal including bituminous coal, lean coal, anthracite and lignite. In addition, it is equipped with different amounts of independent wind barns according to different evaporation capacity, by which users can adjust the wind supply to ensure the complete combustion on the basis of the type of coal and combustion conditions. Meanwhile, ZOZEN also customized feed system, slagging system and tail flue gas treatment system to increase the economic benefits in highest degree.
Gas pressure hot water boiler pressure introduction gas hot water boiler: gas pressure hot water boiler pressure vessel belongs, as always pressure hot water boiler is full of water, so no water level, but to be fitted with pressure gauges, safety valves and thermometers. Circulating pump pressure hot water boiler heating system is generally used in water pump, which is pumping systems engineering backwater sent to the boiler, it is necessary to overcome the resistance of the systemic circulation, but also to maintain a certain pressure boilers, hot water does not guarantee high temperature vaporization . Pressure hot water boiler can not only supply low-temperature water, but also to supply hot water Features: 1, boiler design, manufacturing, supervision and inspection are strictly according to "hot water boiler Safety Supervision" ensure long-term security and stability of the boilers. 2, the boiler body is a shell type three return all wet back downstream pyrotechnic pipe structure, large combustion flame in combustion chamber a slight positive pressure, combustion heat load is low, less NOx emissions of harmful substances. Through advanced machine test bed to test several times to verify the boiler under various load operation can get good thermal performance, qualified flue gas emissions targets as well as a wide range of burner adapter. 3, before and after the boiler smoke box with a special heat insulation materials, high temperature, low thermal conductivity, good anti-radical quenching heat capacity, greatly extending the life of the smoke box. A lower smoke box is provided with a condensate drain, water condensed reduce corrosion of the pressure receiving member. 4, the boiler and each pot spout means disposed reasonable to optimize the pot water circulation, prevent scale generation, but also help to improve the water side heat transfer. Set hand hole, inspection hole in the poor circulation of weak links, to facilitate regular inspection and maintenance. 5, the temperature of the boiler smoke box structure compared to dry wet back boiler back, greatly reduced, the smoke box solves the frequent need to maintain the operation of the phenomenon; 6, a large volume of water boiler design, the load fluctuation of furnace not sensitive to large changes in the load range of users still apply. 7, industrial boilers professional artists and designers carefully designed appearance, novel and unique and yet with the surrounding environment coordination. Sino-Swiss boiler completely changed the image of heavy industrial boilers, industrial boilers is a new concept of low-carbon twenty-first century. Construction and installation points: 1 explosion-proof door is provided on the fuel, the rear of the gas-fired boiler or pipe smoke, explosion door location should be conducive to explosion venting. For gas explosion likely to endanger the safety of the operator occasions, should be installed on the guide tube pressure relief blast doors. 2. Installation of boiler and its auxiliary equipment, water treatment equipment should meet the technical requirements of the device manufacturer. Equipment foundation must be the arrival of equipment and after verification and design drawings before construction. 3. When mounting the device, the device should be avoided, to install the floor material are collected together. Column using a construction, the beam lifting device, must first verify that the carrying capacity of the beam, the column. 4. After the pressure test acceptance oil, gas, water, steam pipe installation, according to "Industrial metallic pipeline construction and acceptance" in GB50235-1997. The main construction practices and node configuration detail see National Building Standard Design Atlas. 02R110 "Gas (oil) boiler room engineering design and construction Atlas" 02R111 "small vertical, horizontal tank Atlas" 02R112 "Tank dome Atlas"
Greater than 65t / h industrial boiler of what air pollutant emission standards should be executed? A: The State Environmental Protection Administration, Central Division-standard [1993] No. 012 document pointed out that the emergence of a small number of parameters currently higher than GB1921-80 "industrial how much is 11ton steam boiler parameters Series" and GB3166-82 "hot water boiler parameters Series" layer burning, stoker boiler, regardless of its use Zanan GB1327-91 execution. Therefore> 65t / h or more (except coal, circulating fluidized bed, and fuel, gas fired boilers) industrial boilers should be performed "boiler air pollutant emission standards."
Recently, Zhongshan City, Guangdong Province, the ecological environment expanded Bureau held a working high-pollution fuel combustion zone ban will promote further urge the major companies on time and quality completion of boiler rectification task. It will be mentioned in the need to deeply Publicizing the newly revised "Air Pollution Prevention Regulations of Guangdong Province" and "boiler air pollutant emission standards" and to implement the next phase of work to expand the scope of the ban on burning zone, Zhongshan City.
District policy is to implement the ban on burning blue sky, Zhongshan City, to win the Battle of the most important, relevant departments, district towns, enterprises should pay full attention and positive action in order to "limit Forced, territorial responsibility, multi-pronged approach , coordinated implementation of the "principle, should work together to create synergy, take the following measures to ensure that all targets are met within the deadline.
According to published Zhongshan City, "about expanding the scope of high-pollution fuel combustion zone ban notice" requirement, in addition to coal-fired cogeneration thermal power plant units have been built high-pollution fuel industrial equipment must be removed or completed by June 30 this year clean energy transformation, all enterprises should actively cooperate with government departments to complete the rectification task on time and quality.
According to requirements "Boiler Air Pollutants Emission Standards" (DB44 / 765-2019), and from April 1 this year, the province's start step by step implementation of the new air pollutant emission standards boiler, new boiler effective from April 1 this year, in accordance with the different regions in which, since 1 July 2019 or 1 July 2020 to implement the new standard boilers. Compared with the original standards, new standards particulate matter, sulfur dioxide, nitrogen oxides and other pollutants received strict emission limits help to further reduce the total emissions of air pollutants.