industrial boiler reconditioning in uk
July 26, 2016, Beijing, China Everbright Paper Co., Ltd. and the company signed a "split 6 tons of steam condensing gas steam industrial boiler reconditioning in uk contract" by the company responsible for the WNS6-1.25-YQ split condensing gas boiler steam to all production, installation and commissioning work. The product is the use of condensing technology, effective emission of harmful substances SOx, NOx, COx, is industrial boilers efficient and environmentally friendly solutions.
Which industrial boiler reconditioning in uk needs to remove dirt alkali cooking? Rust and dirt inside the boiler only affects the output, wasted fuel, reduce steam quality, but also cause overheating burning heating surface, so the timely removal of rust, grease, dirt in the boiler is necessary. Boiler scale commonly used pickling and alkali cooking method to remove, but which require boiler base crabbing? 1. newly installed boilers or pressure element through repair, alteration boiler. Because a certain amount of the boiler into the interior rust, grease and dirt in the manufacture, repair and installation process. 2. Run the knot born some time a certain scale, but does not meet the conditions of the pickling boiler version 99 "boiler chemical cleaning rules." 3. Run a warm period, especially in the Northeast region of China is generally used for heating hot water boilers, and rated each boiler for heat mostly no more than 4.2MW, and the water is basically surface water, suspended solids in water more, after running for some time, more dirt pot residue, after running the heating period, immediately boiling out cleaning, otherwise it will cause electrochemical corrosion under the scale boiler and shorten the life of the boiler
The transformation of hot water industrial boiler reconditioning in uk construction from the perspective of energy security point of view, the boiler is an energy conversion device. In the boiler, the primary energy (fuel) can be converted to a chemical reservoir through a combustion process is a combustion product (flue gas and ash) contained in the thermal energy, and heat transfer to the combustion process in turn an intermediate heat carrier (water through a heat transfer process and steam). It will depend on the heat supplied to the heating apparatus. With the increasingly serious air pollution, Henan fast boiler uses condensing technology, with the continuous optimization of enterprise in Henan fast boiler, condensing technology has been able to meet the environmental requirements in most areas. Of course, the emergence of condensate, gas-fired boiler led to price increases, particularly in the heavily polluted northern cities. Condensing gas boiler is a heating device. When a user receives heat from condensing boilers, they are also aware of the changes condensing technology for environmental requirements. 1. Made of steel - aluminum composite finned tube, condenser and economizer are made of steel - aluminum finned tubes, Nd is made of steel.
If the steam industrial boiler reconditioning in uk if used improperly can cause unnecessary trouble high steam boiler efficiency, strong firepower. They are common production equipment. However, they are also at risk. If used improperly, it can cause unnecessary trouble. Therefore, the explanation must be familiar with the use of steam boilers. Enterprises must attach great importance to the boiler safety. Management is responsible for boiler equipment designated full-time staff, and in accordance with the requirements of good use and management of the boiler. According to the structure of the boiler, combustion and use requirements to ensure safe operation of the boiler operating procedures and explosion-proof, fire prevention, anti-virus security management system, as well as incident handling methods. Developed and strictly enforced. After drinking alcohol is strictly prohibited and unemployment. Should regularly check and maintain the boiler, and no unit shall be compelled to use are security risks of the boiler. Before servicing due drawings and construction technology programs. Maintenance of technical requirements refer to the technical standards and relevant technical regulations boilers. After completion of repairs, technical data such as drawings, material quality certificates and maintenance of quality inspection certificates should be stored in the boiler plant's technical documentation. Prohibit non-boiler room operator to enter the workplace. Outsiders must be approved by relevant leaders or accompanied to enter. When using steam boilers should be very careful, because the damage would be minor differences in the human body. Therefore, in operation Be careful instructions on using steam boilers, and explicit attention to the operation during the operation. Based on years of experience, you need to pay attention to the operation of the steam boiler are as follows: Before operating the boiler, you must be familiar with this manual. This is to protect the normal use of safety equipment and operator. Check start the machine power supply voltage and the water front. Close the drain valve opens the water supply valve, the pump checks whether the jam. After the card is removed, the fan blades of the rear cover is removed, the motor shaft and can be opened to open the flexible state. When testing the boiler or changing accessories, turn off the power to avoid danger caused by the charging operation. Electrical control means should be moisture control box, a pump motor, to prevent combustion. Boiler should be kept clean. The quality requirements of the boiler, be sure to use the water softener device is mounted. Do not use a water softener can cause Boiler. When severe, the scale will lead to the blast tube shorten the life of the boiler. If the above conditions are not caused by the use of water treatment equipment, are not covered under the warranty. Please note that the use of sewage. Once a day should be discharged, the discharge pressure of 0.1MPa-0.15MPa, to prevent clogging of the pipe. Drain should be connected properly to prevent burns. Safety valve should be checked regularly and repaired. At least once a month, you can quickly pull rod safety valve check. Safety valve has the flexibility to take off and return every year by the local Bureau of Technical Supervision check valve on time.