Electric steam boiler flue of accumulating a certain amount of soot how to deal with? Electric steam boiler furnace cleaning backpass long-term non-stop, accumulating a certain amount of soot or carbon black. Solution: When the temperature drops below the flue 50 ℃, check before entering the flue tail heating surface, and should completely remove the flue soot. If not burning, can be re-started ignition; if burning, should be replaced, repaired burning member; large negative pressure of the combustion chamber, so that gas will be no time to burn into the electric steam boiler tail. Solution: When the exhaust gas temperature close to the temperature of the injected steam, or less than 150 deg.] C and more stable during 1h openable inspection hole inspection, after checking element determines the source of fire, the ventilation fans before starting. When shutdown or electric steam boiler fire, air gun valve is not closed. Solution: strengthen the electric steam boiler feed water and turn on the water, open the valve or economizer recirculation tube to protect the economizer being burnt; lower start, the furnace temperature during shutdown, unburned fuel in the furnace . Solution: fire extinguishing devices immediately into steam, carbon dioxide or other fire extinguishing devices; burn improperly adjusted, with insufficient wind or with the wind unreasonable. Solution: Close the flue duct and baffle around the door opening, start sending prohibited, induced draft fan.
The method of adjusting the temperature of the superheated steam heating stove have? The method of adjusting the temperature of the superheated steam heating stove have? DC boiler steam temperature is mainly adjusted by adjusting the quantity of fuel to water. In actual operation, because the efficiency of boiler feed water and fuel heat enthalpy (depends on the water temperature) and the like will change, so the actual boiler operation to ensure the water-fuel ratio of the exact value is not easy. Coal-fired furnace will fluctuate because of the amount of coal and the amount of fuel due to the steam temperature. So, except DC boiler fuel to water ratio as the coarse adjustment means, but also must be used as a method of spray desuperheater means of fine-tuning adjustment. There is also some boiler flue gas recirculation, dampers and methods of the swing center of the flame as an auxiliary adjusting device.
Gas boiler Burner Failures and gas boiler burners Failures and - best  a gas boiler, gas boiler burner ignition misfire rod reasons: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs. Measures following five: Clear, renewal, adjust the distance, change and switching transformer. Second, gas boiler, but spark ignition rods misfire reasons: 1, the cyclone disc space ventilation is blocked carbon, poor ventilation. 2, dirty oil nozzle clogging or wear. 3, the throttle angle is set too small. 4, the firing bar from the leading edge from the oil nozzle tip inappropriate (too protruding or retracted) 5, the first solenoid valve is an oil debris blocking gun (gun small kerosene). 6, oily or too viscous to flow easily clogged or the oil filtration system the valve is not opened, so that insufficient suction pump, oil pressure. 7, the filter pump itself blocked. 8, the oil more water (boiling abnormal noise within the heater). Measures are: Clear; first wash, such as not renewed; turndown test; adjusting the distance (in 3 ~ 4mm as well); Remove cleaning (cleaning the parts diesel); Check tubing and oil filters, insulation equipment ; remove peripheral screw pump, carefully remove the cover inside out oil network, with immersion oil; renewal of the test oil.
Winter heating season is approaching, Jinan City, Shandong Province in response to the country clean, low-emission environmental requirements, increase efforts to support the promotion of winter heating clean, clean heating to further enhance the city level, issued on the issue clean winter heating engineering and operational capital subsidy Notice.
Second, the use of centralized gas boiler user, uniform implementation of preferential gas prices 1.71 yuan / cubic meter, the heating period and after the end of the third-party audit of gas consumption, gas will be the final settlement price (not exceeding Municipality department approved between the reference price) and 1.71 yuan / cubic meter price difference subsidy to the gas company, to purchase heating companies use non-city franchise gas pipeline business gas heating can be direct subsidies to heating companies.
Third, the use of electricity users centralized heating, heating period and by the end of the third-party audit by the electricity, the power company will operate the unit with the settlement price and preferential rates (level of 0.5 yuan / kwh, Valley Electric 0.25 yuan / kilowatt the difference between the time) subsidy to operate the unit.
Fourth, the use of formula household heating boiler user, purchase subsidy subsidy to the user equipment or units in accordance with Standard 2000 underwritten yuan / household. Temporarily performed using the sub-family user heating boiler gas prices during the step, performed in accordance with a first gear price urban gas prices; after the heating period, gas operation subsidies subsidies to users according to standard 1200 / household .
Fifth, the use of household electric heating type user, can also get subsidies. Subsidy ranges: The air source heat pumps, domestic electric boilers, heating cables, heating the carbon crystal plate user. According to the notification, the device according to the purchase subsidy subsidized purchase truly carbon crystal plate does not exceed 2,000 yuan / household air-source heat pump, domestic electric boilers, heating cables subsidy standard is 2000 Yuan / or household user to Advancer units. After the heating period, power to the user according to operating subsidies subsidies 1200 / standard household.