machined bevel shell cover apply to boiler
Use machined bevel shell cover apply to boiler units should strictly enforce the "Special Equipment Safety Act" to ensure the safe use of boilers, boiler units should use boilers meet the safety requirements of technical specifications, the unit in charge of the leadership should use the unit responsible for the safety of boilers, boiler management, boiler team leader, fireman, maintenance workers, laboratory technicians and other water quality of job safety responsibility system, the implementation of the responsibilities of all categories of personnel.
Recently, the Anyang city government released the 2018 benchmark of scientific and technological innovation of enterprises citation, to be commended and encouraged Anyang nine local enterprises. I company with a solid technology skills, steady pace of development and constantly aggressive determination to win awards municipal government. As a high-tech fast square machined bevel shell cover apply to boiler manufacturing enterprises, while maintaining infrastructure, adhere to scientific and technological innovation path of development, follow the development of high-quality, strengthen management, attention to restructuring, rushed development, highlights frequent, becoming the city's technology and industrial double front of the vanguard, Anyang City for a number of honors in the country, enhance the technological competitiveness of the city.
before, and the technology indexes are of leading level in china and even in the world.
thermal efficiency of ZG horizontal fire tube boiler can reach above 98%, the length of boiler furnace rear axle is longer than domestic models, which will prolong the fuel combustion time in the furnace and make coal combustion more efficient, reduce the carbon content of slag; increase the effective area of the grate. The boiler’s overload capability significantly enhanced. Meanwhile it adopts two side air intake technology with which the boiler is equipped with 6 independent air rooms. There is an air regulator set in every air room to reach the best effect.
Note industrial machined bevel shell cover apply to boiler water quality testing of water quality testing what are the considerations which industrial boilers (1) pay attention to scaling problems boiler. When carrying out inspections of the boiler water quality, pay attention to the problem of scale boilers. Boiler heating surface scaling, will not only affect the thermal conductivity of the boiler, but also can disrupt the normal structure of the boiler, affecting the normal operation of the boiler. Fouling will too concentrated so that the temperature of the steel sheet, the steel sheet could afford once over, will produce accidents. Moreover, the scale problem is a common cause of boiler accident, we need to attach great importance to staff fouling problems, do water quality testing. (2) pay attention to water treatment and work-related training of personnel. First, we must strengthen the progress of the work of the boiler water treatment, understand the importance of water treatment. Second, we must strengthen the training of staff so that it can fully understand the water treatment process. To make it have the necessary knowledge of water treatment. In particular, to strengthen the natural water, the impurities in the water for effective treatment to improve water quality. To pay attention when handling method, common in two ways, first, filtration, and second precipitation. In personnel training, to ensure that staff can master the common water quality testing methods and treatment, to master the professional knowledge, and constantly improve the quality of personnel. First, to ensure accurate test results of water quality, so as to smoothly guide the follow-up by the correct data. Second, we must strengthen the technical quality of the staff increase, so do the theory with practice. Third, the development of sound, a sound regulatory framework, the rule-based quality inspection can reduce boiler performance problems caused by poor water quality. (3) prevent boiler corrosion problems. Boiler corrosion problems need attention, which need to focus on sensitive monitoring of the boiler, the weak link in the water quality testing, monitoring whether it is corrosive. If the monitoring to corrosive media, to fully, completely clear. Taking into account the protection of the cold parts of the corrosion-prone parts of timely protection, corrosion has been the site for processing, so that you can effectively avoid the boiler cause further corrosion. (4) strengthen the supervision of water treatment. To further strengthen the supervision of the water treatment process, so as to improve the performance of the boiler, saving operating costs, reduce the occurrence of accidents. First of all, to supervise water quality around the normal operation of the boiler, to avoid adverse water quality. Second, we must strictly examine the quality of treated water in accordance with the relevant requirements, the supervision carried out, to achieve the quality supervision and inspection of the entire process. Only strengthen supervision, the implementation of routine inspections in order to truly improve the effectiveness of water quality tests.