manufacturing range steam boilers
To further promote the comprehensive management of coal-fired boilers, Jincheng City, Shanxi Province, according to "Jincheng Blue win the Battle of three-year action plan" requirements, plans to complete 109 units of 10-20 tons of steam "small coal-fired boilers" within this year the phase-out, at the same time, Jincheng will start working out of 35 tons of steam coal-fired boilers.
This year, Jincheng counties (cities, districts) the environmental sector will urge the relevant enterprises and institutions to eliminate the basis of 10 tons of steam and coal-fired boilers on in 2018 to accelerate the phase-out and 20 tons of steam coal-fired boilers. This year, the city to complete 109 units (10-20 tons of steam boilers) working out of a total of 589.5 tons of steam boilers; at the same time, Jincheng will also speed up the foundation and 20 tons of steam coal-fired boiler out, start 35 tons of steam phase out coal-fired boilers, in principle, within the city's new domain-wide 35 tons of steam coal-fired boilers.
In addition, Jincheng will accelerate the transformation of ultra-low emission. Before the end of September this year, the city will complete 52 units (65 tons of steam per hour and higher coal-fired boilers) coal-fired heating boilers ultra-low total of 4530 tons of steam boilers transformation, and the county (city) built-up area, biomass boilers emissions transformation. After transformation, under condition of the reference oxygen content of 6%, soot, sulfur dioxide, nitrogen oxides emission concentration of these boilers respectively not higher than 10 mg / m, 35 mg / m and 50 mg / m.
Transformation of low nitrogen in the combustion aspect, before the end of October, Jincheng station 610 will complete the transformation of low-nitrogen combustion Total 1940.15 tons of steam gas boiler, after completion of the transformation, the boiler NOx emission will not exceed 50 mg / m.
Boiler equipment use in the food industry needs to pay attention to what issues? As an important special boiler equipment often use a food industry, incorrect operation perhaps a mistake, certainly there will be security problems, if we can understand and grasp the issues early in the application process needs attention, prolong the service life of the boiler together, but also to decrease and even eradicate the occurrence of security incidents. Boiler equipment use in the food industry needs to pay attention to what issues? Learn food industry boiler operator must be familiar with the principles of work-related boiler, bearing a variety of accessories, performance and operating methods. It is understood that the boiler is an energy conversion device, the energy input to the combustion boiler has guessed chemical energy, electrical energy, thermal energy has a certain output of the boiler steam, hot water or organic heat carrier. The hot water or steam generating boiler may be provided directly to industrial production and people's life required energy, such as food processing industry in cooking, blanching, sterilization and disinfection. Comprehensive and carefully view before use, and the persons needs to see burning oil, and each nozzle connection, power supply and burners, pumps condition. Together, also needs to see boiler safety valve, see the pumps, sewerage is normal, view the security annex shall be in the normal position, the water level meter, pressure gauge should be in the open position, deaerator can operate normally, softened the device can operate normally and the normal water level inside the water softener, water pump operation without failure. In the meantime, the safety valve is one of the most important safety equipment boilers, can play in the overpressure timely secretion antihypertensive effect. The process of applying for a timed or manual drain timing function test, to ensure that does not render jam caused by rust safety valve malfunction problem presented. See operating condition after the power is turned on the power switch, to see whether the normal operation of each part, whether a fault signal, if it is found the problem should be the adoption of measures or to see the patches, troubleshooting. It is worth noting that the burner into active cleaning, combustion, partial load, full load operating conditions must arrive pressure, should be a regular sewage, such as a manufacturing range steam boilers rinse water table, the water level and check the furnace and so on.
150 ton circulating fluidized bed boiler service center
Guide Reading: Recently, ZG boiler service center received a schedule from one of our project named 150 tons circulating fluidized bed boiler installation site personnel, a detailed record of the daily work schedule installers and boiler installations need to be resolved. As ZG 150ton circulating fluidized bed boiler service center get a five-star service standards from users.
Compared with ordinary boilers, condensing boilers was good: the popularity of the national energy efficient environmentally friendly ideas, so that all walks of life have undergone significant changes. Enterprises in the purchase of boiler equipment, will be more favored by energy saving boiler, condensing boiler is undoubtedly one of the representative products.