steam pressure 100lbs natural gas fired steam boiler
Industrial gas steam pressure 100lbs fired steam boiler room planning considerations: industrial gas steam boiler room Planning Considerations What? Followed by the degree of technological progress from time to time, the rapid expansion of social economy, people's requirements for industrial gas boiler room planning have become more sophisticated. Now now, in the industrial gas boiler room planning there are still many achievements in urgent need of treatment, therefore, we have to enhance the learning and use of advanced planning practices and advanced technology, from time to time suspend the development and review of industrial gas boiler room planning, the industrial gas boiler housing plan is more suitable, safe, reliable and economical. 2, selection and use of industrial gas boiler at a reasonable selection of urban planning, boiler, environmental management and other mission boiler type is dropped purification, waste power, an important part of reasonable expenses. Set the cost of the boiler is one of the essential elements of when thinking of selection. Because the characteristics of industrial gas boiler itself, the boiler room and equipment to establish a more economical, should be used in high load industrial gas furnace heat boilers in order to reduce the volume of the furnace. Due to the absence of heating surface cleaner, slagging, wear results, the smoke may use a higher speed, reduced scale of the convection heating surface, convection through the rational placement control the industrial gas boiler capacity of coal-fired boiler with a more compact structure, dimensions small, light weight, in order to decrease equipment investment; supporting auxiliary boiler optional satisfactory work. Industrial demand for gas-fired boiler is not equipped with soot blowers, dust, slag and other equipment and fuel dryer slave device, and can save and land acquisition costs placed above equipment; the use of a gas pipeline walks as boiler fuel, not only no fuel storage equipment, supply calm and without prior preparation of fuel processing equipment, greatly simplified the trivial; civil engineering boiler room investment costs and other related costs will lower; no fuel storage, can save shipping costs, place and rest force. Boiler room non-essential equipment such as leak detection equipment for the surge equipment, measurement equipment, gas. Coal, oil, gas boiler three kinds of heat load in the opposite situation, a huge volume of coal-fired boilers, additional slack style drums, Fan, Java machine, dust collector, but also with storage of coal, slag heap place, It covers an area larger. Industrial gas boilers small volume itself, and these need not be equipped with auxiliary equipment, simply set up between a host and auxiliary room, set on more messy, covering economy. Industrial gas boiler city gas source is generally taken from the intermediate pressure gas supply line, the gas pipeline laying gas sampling point to the boiler room, then according to quell's brand, type and caliber regulating device applications, scheduling outlet pressure range, by metering the put into use. Establish a set fee just gas network tariffs, pipeline fees, hot walks pipeline fee. Gas pipeline network overall cost of capital is the sum of the gas company funds charged to the user, it can be determined depending on the circumstances around the gas company. Usually adopted buried gas pipeline type, buried depth is generally about 0.8m ~ 1.0m, seamless steel pipe can be selected or PE pipes, pipe surrounding sand 15cm ~ 20cm plating, hot water pipe laying relatively simple, somewhat messy steam pipe walks . 3, industrial gas boiler room planning results in the presence of 3.1. Selection of the size of the heat load of the boiler and its expansion tend to choose the boiler capacity, the number of great links. The larger heat load, single boiler capacity should be large. The near future can be greatly increased thermal load, it is also relatively large capacity boiler can choose, it will expand the load thought. The only thought to increase the long-term thermal load, the expansion device may leave the boiler placeholder deployment end in the boiler room, or space left on the total FIG. However, in the practice of project planning, often there is a lack of expansion heat load estimates, constitute improper boiler selection, pre-operation to cause unnecessary trouble. 3.2. Gas boiler gas regulator trivial results generally used in high-pressure (less than 5kPa) and medium voltage (5 ~ 150kPa) trivial. Gas usually before entering the boiler room will arrive this requirement. Now the gas hot water boiler is equipped with a high level of automation subsided, a calm requires the gas pressure is lower, so before further demand into a calm pace pressure boiler manufacturers themselves generally equipped. Gas pressure regulating trivial demands reliable equipment, but on the size of the gas pipeline valve is open due to the gas pressure when scheduling the gas pressure is high or low, and tempering will cause off, start and stop frequently subsided's configuration, thereby affecting the boiler work. 3.3. Gas boiler quality results planning standard gauge, the quality can not be ensured when the gas, should be provided or dust, oil and water, respectively, and a total closed drain valve before the gas main pipe before the regulator device. Most of the oil production plant in the use of oil with anger, it is often said of moisture in the summer cold weather, moisture and light hydrocarbons and other substances containing moisture, condensation will constitute a line blockage, an initiative to quell the flame, impact Heating. 3.4. Chimney condensate results because of the high thermal efficiency of industrial gas boiler, a low exhaust gas temperature, typically 180 degrees, the boiler room planning criteria (GB50041-2008) rules industrial gas boiler room chimney should be reinforced concrete or steel chimneys chimney. Chimney will appear directly in the outdoor summer steel chimney condensate freezing results, constitute icing light rusty steel chimney, would constitute a temporary corrosion, freezing severe affect chimney smoke. 3.5. The amount of air to quell the outcome's when quell Industrial gas boiler is in the boiler room, the air between the boiler must be satisfied the requirements apply to quell the device, otherwise there will be no abundant natural gas to quell working carbon monoxide poisoning.
Gas fired boilers into boilers which benefit: the traditional coal-fired steam pressure 100lbs fired steam boiler in the use of the process releases large amounts of carbon dioxide, sulfur dioxide and other harmful gases, causing serious air pollution and acid rain, and coal are non-renewable resources, Earth the storage capacity is limited, and the price of coal is relatively high with the successive implementation of the national policy of reform coal, coal-fired boiler traditional high pollution and high consumption market gradually been criticized, many provinces and cities have started from coal to gas work, namely the traditional coal-fired boilers to become clean non-polluting gas boilers, and strive to achieve the unity of economic and social benefits. In conventional coal-fired boilers used in the process releases large amounts of carbon dioxide, sulfur dioxide and other harmful gases, causing serious air pollution, and acid rain, while the coal are non-renewable resources, the limited storage capacity on the earth, and the price of coal is relatively higher, therefore, imperative coal to gas has the advantage.
Fast boiler is a very trustworthy business, whether it is the beginning of cooperation or boiler put into operation, such as a party soon have maintained cooperative attitude, patience, careful. To ensure long-term stability of the latter part of the boiler operation, fast boiler technician fireman's gave us a free people to do the training, precautions and reduce the accident rate method full guidance boiler operation. --customer feedback
Steam boiler pressure gauge should pay attention to matters 1. The rated steam pressure less than 2.45MPa steam pressure 100lbs fired steam boilers, pressure gauge accuracy of not less than 2.5; equal to the rated boiler steam pressure 2.45MPa, the pressure shall not be less than 1.5. Electric heating boiler and the boiler is mainly composed of electric control box and control system. Its characteristics are environmentally friendly, clean, no pollution, no noise, automatic, with limited energy and reduce prices significantly, as a new boiler electric heating boiler equipment increasingly being recognized. Electric heating the core member is electrically heated boiler, directly determines the life of the boiler, to select a non-metallic electrical heating tube (such as a ceramic heating pipe), because it is resistant to the load, a long life, and a water separation structure, the boiler Wing no leakage. There are heating and hot water boiler bath for two purposes. Hot water boiler by circulating hot water circulation pump hot water holding tank, the tank hot water heating cycle can be achieved bath object; hot water boiler by circulating hot water circulation pump heating conduit, through the heat sink (radiator) people can achieve heating requirements; hot water boiler and hot water circulating pump with heat exchanger can be achieved bathing and heating dual function. Dial gauge diameter of not less than 100 mm, to ensure that the operator can clearly see the surface pressure indication. 2. On the dial gauge steam boiler should draw a red line to indicate the maximum allowable working pressure. 3. The steam boiler pressure gauge should be installed in place to facilitate the observation and purged, and should prevent high temperature, vibration and icing. 4. The steam boiler pressure gauge should be checked at least once every six months, to be sealed lead-sealed after calibration. 5. The steam boiler gauge connection tube not leak water and steam, otherwise it will reduce the pressure instruction value. 6. A steam boiler pressure gauge measuring range should be compatible with the operating pressure of the device under test, the working pressure is generally 1.53 times, preferably 2 times the working pressure. Steam boiler no pressure gauge, pressure gauge or pressure gauge damage does not meet the requirements. When the steam boiler pressure gauge of the following circumstances, should stop using: 1. The surface of the glass or the dial pins; Lead seal, lead seal is broken or exceeds the calibration period; when no pressure gauge pointer position is limited to the limit staple nail can not be restored, and the rank unlimited gauge pointer movement from zero data is out of range pressure layer. Poor; leak or pointer jitter in the meter; other defects affect the accuracy of the pressure gauge. The use of the accumulator: the accumulator for a hydraulic system of the machine intermittently. It may be a low speed motion or intermittent motion of the actuator, the oil reservoir of the hydraulic pump, when rapid movement of the actuator requires a large flow rate, as an auxiliary energy supply to the system together with the hydraulic pump, enabling the pump and the entire hydraulic system miniaturization, to achieve energy saving. Hydraulic shock absorber valve and the opening and closing of rapid mutation load, the system generates a pressure shock, loved one causes vibration and noise and even damage the machine. The accumulator can relax and absorb the impact pressure of the liquid. Accumulators absorb and reduce the pressure pulsation flow pulsation and various hydraulic pumps, thus reducing noise and vibration system. The function of the gas spring having a damper, the vibration can be used to walk between the car body and the wheel and other mechanical absorption. The accumulator may be balance gravity vertical actuator (hydraulic cylinder) and the potential energy absorbing load drop into hydraulic energy storage, while producing speed resistance. When the rising vertical actuator, the accumulator absorbs energy of the original release, and together with the oil pump to the hydraulic cylinders, so as to achieve balance and energy.